Irrigation Equipment Directory

Drip Zone and Flow Design Worksheet

This worksheet sizes drip zones so that each one matches your pump supply. You enter row spacing, emitter spacing and flow, and it returns gpm per acre and zone size.

Why it matters

Zones that exceed pump capacity run at low pressure and water unevenly. Zones that are too small raise valve and labor costs. A written calculation gives the right balance before you buy pipe.

Step by step

  1. Write row spacing in feet, and calculate row feet per acre by dividing 43,560 by that spacing.
  2. Write emitter spacing and flow, and calculate gpm per 100 feet of row from those two numbers.
  3. Multiply gpm per 100 feet by row feet per acre divided by 100 to get gpm per acre.
  4. Divide about 90 percent of pump supply by gpm per acre to find the maximum zone acres.
  5. Divide required depth in gallons per acre by gpm per acre to find run time per zone.

What good looks like

A good worksheet gives whole-number zones that fit supply with a margin, lists run time per zone and shows that all zones finish within the hours you can pump each day.

Worked example

Illustrative: rows 4 feet apart give 10,890 feet per acre. Emitters 1 foot apart at 0.2 gph give 20 gph, or 0.333 gpm per 100 feet, so 36.3 gpm per acre. With 135 gpm usable, zones are up to 3.7 acres. For 0.2 inch per day, 5,431 gallons over 36.3 gpm is 150 minutes.

Common mistakes to avoid

  • Forgetting to convert emitter flow from gallons per hour to per minute.
  • Using full pump flow with no margin for filter and pipe losses.
  • Sizing zones from average rather than peak crop use.
  • Designing run times too long to finish in available pumping hours.

Safety, legal and compliance notes

Pump, electrical and backflow work must meet local codes. Have a licensed professional handle motor wiring, and confirm any water use limits with your local water agency before expanding irrigated acres.

What to record

Keep a dated equipment file: purchase date and cost, model and serial numbers, nozzle and sprinkler package charts, pump curves, inspection and repair history, parts replaced, flow and pressure readings and energy use. Good records help you plan replacements, prove performance and support warranty or insurance claims.

When to ask for help

Electrical, well, backflow and chemigation rules vary by state and utility. Talk with the equipment manufacturer or dealer, your extension irrigation specialist, your NRCS or conservation district office, a licensed electrician and your electric utility before you install, modify or repair major equipment. The state directory lists agencies and resources in every state.

Frequently asked questions

Why use 90 percent of pump flow?

Filters, valves and pipe friction reduce usable flow, and pumps wear. A margin keeps zones running at design pressure.

How do I turn gph into gpm?

Divide gallons per hour by 60. For example, 20 gph is 0.333 gpm, which you then scale to your row length.

What if my zones need too many hours?

Add zones capacity, increase pump supply, use higher flow emitters or shorten rows. Each option changes the worksheet numbers.

Related guides

More from the network

Farm news, humor and ranch life at farm.FM.