Irrigation Equipment Directory

Pivot Nozzle and Uniformity Check

A catch-can test measures how evenly your pivot applies water. You set out cans, run the pivot over them, and calculate a uniformity score from the depths collected.

Why it matters

Uneven application wastes water and fertilizer and leaves crop stress in dry bands. A yearly test catches worn nozzles, plugged heads and wrong packages before they cost you yield.

Step by step

  1. Set straight-sided cans in a line along one span, spaced evenly, with tops level at crop height.
  2. Run the pivot over the cans on a calm day, then measure each can's depth in inches.
  3. Record readings, compute the average, and find each can's difference from that average, ignoring the sign.
  4. Average those differences, divide by the average depth, subtract from one, and multiply by 100 to get uniformity.
  5. Match low and high cans to their outlets, then repair nozzles and recheck.

What good looks like

A good pivot scores in the 90s on uniformity with no clusters of low cans. Any cluster points at one head or one span, and the fix is usually a nozzle or regulator.

Worked example

Illustrative: ten cans read 0.48, 0.52, 0.50, 0.44, 0.56, 0.50, 0.46, 0.54, 0.50 and 0.50 inch. They sum to 5.00, average 0.50. Absolute differences total 0.24, average 0.024. Uniformity is 100 times (1 minus 0.024 over 0.50), or 95.2 percent.

Common mistakes to avoid

  • Testing in wind that blows spray away from the cans.
  • Spacing cans unevenly and not weighting outer cans for their area.
  • Using cans with sloping sides that distort the readings.
  • Reading cans late after evaporation has lowered the depth.

Safety, legal and compliance notes

Work near a moving pivot carries electrical and crushing hazards. Stay clear of towers while running, lock out power before touching equipment, and ask a pivot technician to correct repeated pattern faults.

What to record

Keep a dated equipment file: purchase date and cost, model and serial numbers, nozzle and sprinkler package charts, pump curves, inspection and repair history, parts replaced, flow and pressure readings and energy use. Good records help you plan replacements, prove performance and support warranty or insurance claims.

When to ask for help

Electrical, well, backflow and chemigation rules vary by state and utility. Talk with the equipment manufacturer or dealer, your extension irrigation specialist, your NRCS or conservation district office, a licensed electrician and your electric utility before you install, modify or repair major equipment. The state directory lists agencies and resources in every state.

Frequently asked questions

What uniformity score is acceptable?

Scores in the 90s are generally good for pivots. Lower scores deserve investigation, especially if low cans cluster around one outlet.

Why does spacing matter?

Outer cans represent more field area than inner ones, so unweighted averages can hide problems. Use even spacing and consider area weighting.

How often should I test?

Once a year at least, and again after any nozzle change, major repair or noticeable pattern problem in the crop.

Related guides

More from the network

Farm news, humor and ranch life at farm.FM.