Pump Startup and Shutdown Checklist
This checklist walks through every start and stop of an irrigation pump in order. Using the same steps each time protects the pump, motor and pipe, and gives you readings to compare from week to week.
Why it matters
Most pump damage happens at start and stop: running dry, slamming valves, water hammer and overloaded motors. A short routine that you repeat costs a couple of minutes and prevents repairs that can cost days of lost irrigation.
Step by step
- Before start: check for leaks, guards, oil levels and a clear intake, and confirm downstream valves are set for flow.
- Prime centrifugal pumps fully, and confirm turbine pumps have pre-lubrication or water on the column if your design requires it.
- Start with the discharge valve partly open, then open it gradually over about 30 to 60 seconds while watching pressure.
- After five minutes, log discharge pressure, amps, flow and any unusual noise, vibration, heat or leaks.
- For shutdown, close the discharge valve slowly, stop the pump, confirm check valves seated, and record the hour meter.
What good looks like
A good run shows pressure rising smoothly, amps within the motor's rated limit, no vibration or hot spots, and logged readings that match earlier entries. Shutdown is quiet, with no water hammer or reverse spinning.
Worked example
Sample row: Date 6/12, hour meter 1,204, start pressure 45 psi, running pressure 60 psi after 5 minutes, flow 480 gpm, amps 42 against a nameplate rating of 48 amps. Load is 42 divided by 48, or 87.5 percent of rating. That is within limits, so file it as a baseline, and investigate if later rows drift more than about 10 percent.
Common mistakes to avoid
- Starting a centrifugal pump that is not primed, which burns seals within moments.
- Slamming discharge valves open or closed and causing damaging water hammer.
- Skipping the amp reading, so overload trends are missed until the motor fails.
- Leaving the log blank, which removes the baseline needed for troubleshooting.
Safety, legal and compliance notes
Always lock out and tag the power before opening a pump, guard or panel. Electrical work, motor starters and fuel systems should be handled by a licensed electrician or qualified service technician.
What to record
Keep a dated equipment file: purchase date and cost, model and serial numbers, nozzle and sprinkler package charts, pump curves, inspection and repair history, parts replaced, flow and pressure readings and energy use. Good records help you plan replacements, prove performance and support warranty or insurance claims.
When to ask for help
Electrical, well, backflow and chemigation rules vary by state and utility. Talk with the equipment manufacturer or dealer, your extension irrigation specialist, your NRCS or conservation district office, a licensed electrician and your electric utility before you install, modify or repair major equipment. The state directory lists agencies and resources in every state.
Frequently asked questions
How long should I watch a pump after starting?
Watch for at least five minutes, then check again after an hour. Early problems show in pressure, noise, heat and amps before they become failures.
Why open the discharge valve slowly?
Slow opening lets air escape, fills pipe gently and avoids pressure surges that stress pipe, fittings and the pump. Always follow your system designer's guidance.
What should I log every start?
Record date, hour meter, pressure, amps, flow if metered, and any unusual observations. A short consistent record is far more useful than a long irregular one.
Related guides
- How Irrigation Pumps Work
- Pump Selection Basics
- Pump Efficiency and Energy Cost Worksheet
- Electric vs Diesel Irrigation Power
- Irrigation Filtration Basics
- Choosing a Filter Type
More from the network
Farm news, humor and ranch life at farm.FM.