This log records regular checks of every sensor, controller and valve. Each line lists the device, what you tested, what you expected, what you found and what you did, so drift and failures show up early.

Why it matters

Controls fail quietly. A dead battery, drifting sensor or sticking valve can waste water or leave a zone dry for weeks. A dated log turns small anomalies into planned repairs instead of costly mid-season emergencies.

Step by step

  1. Set up columns: date, device and location, check performed, expected value, found value, difference, action taken and initials.
  2. List every device once, add one row per check, and keep the log in the pump house.
  3. Test sensors against a hand probe or shovel check, and test controllers by running each zone manually.
  4. Compute the difference as found minus expected, and set a pass limit for each type of check.
  5. Repair or replace anything outside its limit, then re-check and note the result on the next line.

What good looks like

A good log is complete, dated and consistent. It shows each device passing on schedule, records out-of-limit results with fixes, and lets you spot recurring failures in the same device or location.

Worked example

Sample row: 4/10, controller zone 3, manual run test, expected 120 minutes, found 118 minutes. Difference is 118 minus 120, or minus 2 minutes, which is 2 divided by 120, or 1.7 percent, within a 5 percent pass limit. Second row: 4/10, sensor battery, expected above 3.0 volts, found 2.9 volts, outside limit, so replace the battery now and recheck it.

Common mistakes to avoid

  • Logging only failures, which leaves no record of normal results to compare against.
  • Using different check methods each time, so results cannot be compared.
  • Skipping valve checks and finding stuck valves only when crops wilt.
  • Setting no pass limits, so every reading seems acceptable and nothing gets fixed.

Safety, legal and compliance notes

Battery changes, wiring and valve solenoid work involve electricity and pressurized water. Ask a licensed electrician or certified irrigation professional to handle anything beyond simple, low voltage checks you are trained to perform.

What to record

Keep a dated equipment file: purchase date and cost, model and serial numbers, nozzle and sprinkler package charts, pump curves, inspection and repair history, parts replaced, flow and pressure readings and energy use. Good records help you plan replacements, prove performance and support warranty or insurance claims.

When to ask for help

Electrical, well, backflow and chemigation rules vary by state and utility. Talk with the equipment manufacturer or dealer, your extension irrigation specialist, your NRCS or conservation district office, a licensed electrician and your electric utility before you install, modify or repair major equipment. The state directory lists agencies and resources in every state.

Frequently asked questions

How often should I use this log?

Check at season start, then monthly during the irrigation season, and after any storm, outage or repair. Critical zones may justify more frequent checks.

What pass limit should I set?

Choose a limit that matters agronomically, such as a few percent on run time. Keep the same limit across seasons so trends are meaningful.

Should I keep paper or digital records?

Either works. Choose the format you will actually fill in, and back it up. A paper log in the pump house can be as useful as a spreadsheet.

Related guides

More from the network

Farm news, humor and ranch life at farm.FM.